Monday, April 22, 2013

dioxin testing in Israel not 2013


The report on the mission of the planned forage testing laboratory at the Veterinary Institute (VSAH)  in Bet Dagan is now available here

Excerpts from the dioxin section:

3.4.2 Dioxins and dioxin-like chemicals (DLC) Dioxins and dioxin-like compounds (DLC) are by-products of various industrial processes, and are commonly regarded as highly toxic compounds that are environmental pollutants. Dioxins have been considered highly toxic and able to cause reproductive and developmental problems, damage the immune system, interfere with hormones and also cause cancer. This is based on animal studies. Because dioxins refer to such a broad class of compounds that vary widely in toxicity, the concept of toxic equivalence (TEQ) has been developed to facilitate risk assessment and regulatory control. Toxic equivalence factors (TEFs) exist for seven congeners of dioxins, ten furans and twelve PCBs. The reference congener is the most toxic dioxin 2,3,7,8-tetrachlorodibenzo-p-dioxin (TCDD) which per definition has a TEF of one.


Dioxins are not intentionally produced and have no known use. They are the byproducts of various industrial processes (i.e., bleaching paper pulp, and chemical and pesticide manufacture) and combustion activities (i.e., burning household trash, forest fires, and waste incineration). Dioxins and PCBs are randomly present as contaminants in the environment and dietary intake represents the most common route of human exposure. PCBs and dioxins have similar physical and chemical properties. They are both lipophilic and persistent compounds that accumulate in the food chain, consequently biological samples often contain both dioxin and PCB congeners.
Foods of animal origin are the greatest source of human exposure to these contaminants and animal feeds may be an important source of contamination for livestock. Contaminated fats or oils added either intentionally or unintentionally to manufactured feeds can be a source of dioxins and PCBs. These industrial pollutants may be emitted into the air contaminating soil and water and remaining deposited on pastureland. In this case grass-fed animals in highly contaminated areas may give rise to unsafe food products. Maximum levels of these contaminants allowed (table provided in report) in feed and foods of animal origin have been established in some countries, but existing limits are quite variable.
The ultimate aim of toxicology and food/feed safety lab is to be able to lay down in a guideline for efficient and effective management of a contamination incident the maximum time period which should be observed between sampling and report of the analytical result. If the VSAH labs are not be able to accomplish this within the set period and a country faced with the situation of PCBs/dioxin incident in the feed and food
chain VSAH will need to take the appropriate decisions and use laboratories which can comply with the set time period.
The EU reference laboratory for dioxins and PCBs (State Institute for Chemical and Veterinary Analysis of Food, Freiburg, Germany) introduced a detailed view on laboratory capabilities needed for management in dioxin crisis situations.
• The usefulness of the use of CALUX assays and the time needed to obtain first results from use as screening method and confirmed results of suspected samples (eventually differentiated for different matrices : feed materials, compound feed, meat, milk, eggs, ....) in case of a contamination incident.
• the time needed to get a reliable result using GC/HRMS methods (eventually differentiated for different matrices: feed materials, compound feed, meat, milk, eggs, ....) in case of a contamination incident;
• the usefulness of animal biopsy samples to verify compliance with EU legislation.
• Any other useful information related to the sampling and analysis to manage effectively and efficiently a major dioxin contamination incident.


חדשות ערוץ 2

24/04/2013
"אין מניעה להמשיך לאכול ביצים"
פרשת ביצי הדיוקסין עוררה דאגה ושאלות רבות בקרבי גולשי חדשות 2 באינטרנט. האם יש להפסיק או להפחית את אכילת הביצים? האם יש הנחיות מיוחדות לגבי אופן אכילת ביצים מעתה, ומה הוא בעצם אותו חומר בעל השם המאיים "דיוקסין" - התשובות לפניכם
משרדי הבריאות והחקלאות הורו להפסיק את שיווקם של ביצים שמיוצרות במספר משקים בישראל, זאת לאחר שבבדיקות מעבדה שבוצעו בהולנד נמצא כי הביצים מכילות שיעורים גבוהים של חומר המכונה דיוקסין, שבצריכה ממושכת עלול לגרום להתפתחות מחלת הסרטן ולבעיות שונות במערכות הגוף - העצבים, המערכת החיסונית ועוד. הידיעה שפורסמה אמש לראשונה במהדורה המרכזית עוררה שאלות רבות בקרב גולשי חדשות 2, שלשאלותיהם אנחנו מנסים לספק כאן תשובות.
עם זאת, במשרד הבריאות מבהירים כי נזקים בריאותיים עלולים להיגרם רק עקב צריכה ממושכת של החומר במשך חודשים או שנים, וכי הריכוזים שזוהו בבדיקה אינם מהווים סיכון של ממש לאדם הממוצע. מדובר בארבעה משקים קטנים שאותרו במקומות שונים ברחבי הארץ, ובביציהם אותר הריכוז הגבוה של הדיוקסין. כל הביצים נפסלו לשיווק מיד עם מציאת החומר.
גולשים רבים שאלו אילו נזקים עלול לגרום הדיוקסין, האם יש להיזהר מעתה באכילת ביצים, והאם ילדים רגישים יותר לפגיעה מהחומר. במשרד הבריאות הבהירו היום כי אין מניעה להמשיך לאכול ביצים. במשרד הוסיפו והסבירו כי גם אם אוכלים בטעות ביצה נגועה, לא נגרם נזק ממשי. כל הביצים בכללן מכילות דיוקסין שהוא חומר טבעי שנוצר מעצמו, בניגוד לדוגמה לאנטיביוטיקה. בביצים האמורות נמצאה חריגה, ועל כן הן נפסלו.
"הערכים של דיוקסין במדינת ישראל לפי בדיקה שנערכה בחלב אם, שזה המדד המשקף את שיעור דיוקסין באוכלוסייה, נמוכים ביחס לעולם וביחס לרמה המותרת", הוסיפו היום במשרד. הבדיקות שתוצאותיהן התפרסמו אמש נעשו השנה. הם בדקו משקים מכל הארץ ומצאו 3 מהם עם ריכוז של דיוקסונים. אנשי משרד החקלאות ניסו למצוא את הגורם המקשר בין שלושת המשקים, ולאחר בדיקה ממושכת גילו כי כולם מקבלים את המזון לחיות מאותו בית תערובת. זה היה הקשר היחיד בין המשקים.
"דיוקסין זה חומר שנוצר בטבע", הסבירו לנו היום, "בניגוד לאנטיביוטיקה, דיוקסינים יכולים להימצא גם בלי שיוסיפו אותם. לגופו של עניין, זה זעיר אנפין", הוסיפו גורמים המקורבים לנושא. "מדובר בשלושה משקים ובעשרות עד מאות ביצים, מתוך מכלול של לא פחות מ-2 מיליארד בשנה".
"זה היה מטריד הרבה יותר אם היינו מוצאים אנטיביוטיקה, שאינה נוצרת באופן טבעי", אמרו גורמים המעורים בבדיקה. "כמות הביצים שצריך לאכול ביום כדי באמת להפגע מהחשיפה הזו, כיוון שזה נזק מסתבר, היא לא כמות שאדם נורמלי צובר". יש לשוב ולהזכיר שבמשרד הבריאות לא שינו את המלצתם שלא לאכול ביצים חיות, אלא ביצים שעברו הליך חימום כלשהו - טיגון, אפייה או בישול.




ישראל היום

משרדי הבריאות והחקלאות פסלו לשיווק ביצים מארבעה לולים, לאחר שבבדיקה שגרתית התגלו ריכוזים גבוהים של דיוקסינים - חומרים רעילים ומסרטנים - בריכוז גבוה מהמותר.
·         מיטל יסעור בית-אור
פורסם ב
 24.04.2013 01:38
משרד הבריאות ציינו שהעופות יושמדו וששיווק הביצים נאסר. כמו כן נמסר שאין חשש כי מי שאכל את הביצים הללו נמצא בסכנה מיידית, משום שההשפעה של הדיוקסינים היא מהצטברות לאורך זמן בגוף האדם ובכמויות גדולות בהרבה מאלו שנמצאו.
המשותף לארבעת הלולים הוא מקור זהה של מזון לעופות, ונבדק חשד שמקור החשיפה של העופות לדיוקסינים היה מהמזון.
דיוקסינים הם חומרים מזהמים ורעילים שהם תוצרי לוואי של תהליכים תעשייתיים, למשל ייצור חומרי הדברה או שריפת פסולת מוצקה, ושל תהליכים המתרחשים בטבע דוגמת שריפת יערות או התפרצות וולקנית. משך חייהם ארוך והם נמצאים בקרקע, במים, באוויר וגם במזון ובגוף האדם. בכמות גדולה דיוקסינים נחשבים לחומר מסרטן וכן עלולים לפגוע במערכת העצבים, בפוריות ועוד.





JPost.comBreaking News
High levels of toxic chemical dioxane found in chicken eggs By REUTERS
04/24/2013 09:53
The Ministry of Health has barred the marketing of eggs from four farms after high levels of the chemical dioxane were discovered, Israel Radio reported.  

Increased exposure to the chemical may have carcinogenic effects. The ministry has opened an investigation and is investigating the food sources of the chickens as a possible source of the dioxane.   

That's dioxin or maybe dioxine but I am not familiar with dioxane.  I guess that is one of the drawbacks of radio news.

.




Thursday, February 14, 2013

hormones and ecology 2013


This is our abstract for INTECOL 2013 (International ecology society)  

Soil microbial-community response to exogenous steroidal sex hormones under field conditions
G. Hermanna,   L.S. Shoreb, Y. Steinbergera,*
aThe Mina and Everard Goodman Faculty of Life Sciences, Bar-Ilan University,
Ramat-Gan 52900, Israel
bKimron Veterinary Institute, Beit-Dagan, Israel
Abstract
Cattle manure contains a wide range of bio-active components and is widely used as an organic amendment in agroecosystems. One such group of bio-active components in manure that may induce abnormal development of the endocrine system in organisms is the sex hormones (estradiol, estrone, progesterone, testosterone). For example, very low levels of estrogen (ng/L) are needed to cause feminization in male fish while the concentration in cow manure is nearly 1000 µg/kg dry wt. We, therefore, determined the effect of the addition of steroids under field conditions on one of the major components of the soil milieu - soil microbial community, testing its respiration rate (CO2 evolution) as well as activity following stimulation with glucose [microbial biomass (MB)], and the soil microbial community’s  ability to use steroid mammalian hormones [hormone utilization (H-U)]. Steroids (estradiol, estrone, and testosterone) were applied in environmentally relevant concentrations dissolved in 2.5 l water on 0.25 m2 plots in triplicate, and comparison was made with plots receiving water alone. Soil samples were taken from the 0-5, 5-10, and 10-20–cm soil layers. MB, CO2 evolution, and H-U ability were examined at five different times post-treatment (0.5, 3, 4, 5, and 25 days).  Significantly higher MB and CO2 production were found all five times in the upper soil level but not in the lower soil levels (estradiol=estrone>testosterone). The addition of steroids in vitro to the soil samples with prior exposure in situ resulted in increased CO2 production by upper-soil–level samples but generally a lower utilization of steroids in the lower strata. Our study suggest that the increase in MB seen under field conditions in the upper soil level following exposure to steroids is the result of increased capacity of the soil bacteria to mineralize the steroids. 

Monday, July 30, 2012

Japanese dioxin sampling devices




Japanese law for dioxin

Dioxin emissions from waste incineration facilities in Japan are regulated under the dioxin control special law. This law requires every facility owner to conduct an emission test at least once a year according to authorized test method JIS K0311.   The JIS (Japanese Industrial Standards) covers both dioxin analysis method and sampling method.  The latter was revised in 2005 to increase one sampling method of Type I to three different sampling methods of Type I through Type III, which is the so called "cooled probe method" of EN1948.  EN 1948.  EN is European Standard ( European Norm or Norme ).


Type I   



This is the old method. It uses a glass fiber filter with an adsorbent  (styrene-divinyl benzene co-polymer).  For some reason XAD-2, a popular absorbent, "was not in the case of recommending this". 


Type II

Well, as one can easily imagine, an apparatus requiring chilling liquid in ice or dry ice might be very troublesome to maintain, so they used this system which used some special absorbent which I am not acquainted with.





Type III

Now, as engineers like to do, it is easier to take care of the problem at the beginning and not at the end.  If you use a cooling probe which reduces the air temperature to 20

degrees or less, then the liquid can absorb the dioxin at ambient temperature.




Some special use devices have also been developed.

Outdoor sampling device




From Sibata Scientific Technology






The HV-1000R and 700R are samplers intended for outdoor use. These products sample suspended dust in the open face, and provide quantitative analysis of dust concentration and composition. High-accuracy flow rate control is provided by a differential pressure detection system, and instantaneous and cumulative flow rate values are displayed digitally. Reductions in suction flow rate due to increased dust collection are minimized thanks to a constant flow rate function. This product can be used to collect airborne dust by attaching the through pipe. Similarly, it can also be used to collect dioxins by attaching the shuttle tube (tube for polyurethane foam attachment). It is capable of stable, high flow rate sampling, and so can be used under a wide range of conditions as an airborne toxic
.substance sampler


This portable device can handle 800 L/min
It has a shuttle tube with a polyurethane foam filter and quartz fiber filter








Saturday, May 19, 2012

dioxin testing in Israel not 05


What is CALUX?

The CALUX Bioassay

The chemically activated luciferase gene expression (CALUX) in vitro cell bioassay is a bioanalytical tool increasingly used by research and commercial laboratories for screening of dioxins and dioxin-like compounds in sample extracts. The assay is based on aromatic hydrocarbon receptor (AhR)-mediated firefly luciferase expression in genetically modified rat or mouse hepatoma cell lines that express firefly luciferase upon exposure to dioxins or dioxin-like compounds. Since CALUX analyses provide a biological response to all Ah-receptor active compounds present in a sample extract, interpretation of results is much more complex than that of chemical analyses, as an array of parameters affects the results. The Bioassay Research Laboratory at EU-RL for Dioxins and PCBs examines critical methodological parameters and aspects of the CALUX bioassay that can affect quality and accuracy of the analyses.

CALUX technology comprises various fields of work and attention: Cell culturing and maintenance, sample fat extraction, followed by selective clean-up techniques, exposure of cultured cells to cleaned-up sample extracts containing dioxins and/or dioxin-like compounds, measurement of luciferase activity and statistical evaluation and interpretation of results.

Performance Evaluation of the CALUX Technology
Biologically based techniques hold the promise of screening large numbers of samples and greatly decreasing the time and cost of analyses. These techniques are based on the measurement of cellular response produced by enzyme activation. As one of the tasks assigned by the European Commission, the performance of bioassay technology available on the European market is evaluated with regard to their suitability for routine use by European official laboratories, namely, the DR-CALUX [BioDetection Systems (BDS), Netherlands], involving genetically modified H4IIe rat hepatoma cells, and the XDS-CALUX [Xenobiotic Detection Systems, USA] technologies, the latter originating from the research laboratories of Prof. M.S.Denison, University of California Davis (USA), involving genetically modified H1L6.1c3 mouse hepatoma cells. Included in the scope of EU-RL’s activities were also H1L6.1c3 mouse hepatoma cells directly obtained from Prof. M.S.Denison, for research purposes. 
So there are two companies selling CALUX.  BDS was the first to present in Israel at a seminar held at Bactochem, Nes Ziona.  However, it was felt their price structure was too expensive so contacts were made with the US company XDS which had a much more reasonable licensing procedure.


Here are some illustrations from XDSI site
XDS-CALUX® cell mechanism


The AhR receptor complex is capable of binding dioxins, furans, PCBs and other dioxin-like compounds. Once these chemicals bind to the AhR, the complex migrates into the nucleus where it specifically binds to the ARNT protein. The resulting chemical: AhR:ARNT complex then binds to a specific DNA sequence, the Dioxin Responsive Element (DRE), which is present upstream from many genes including that of CYP1A1, and this binding stimulates expression of the adjacent gene.
Dose response curves of the XDS-CALUX® assay to
various PCDH


Diagram of XDS’s separation scheme and the activity



Comparison of XDS-CALUX® to HR GC/MS









Full method at


4435 - 1 Revision 0
September 2007
METHOD 4435

METHOD FOR TOXIC EQUIVALENTS (TEQS) DETERMINATIONS FOR DIOXIN-LIKE CHEMICAL ACTIVITY WITH THE CALUX® BY XDS BIOASSAY
SW-846 is not intended to be an analytical training manual. Therefore, method procedures are written based on the assumption that they will be performed by analysts who are formally trained in at least the basic principles of chemical analysis and in the use of the subject technology. In addition, SW-846 methods, with the exception of required method use for the analysis of method-defined parameters, are intended to be guidance methods which contain general information on how to perform an analytical procedure or technique which a laboratory can use as a basic starting point for generating its own detailed Standard Operating Procedure (SOP), either for its own general use or for a specific project application. The performance data included in this method are for guidance purposes only, and are not intended to be and must not be used as absolute QC acceptance criteria for purposes of laboratory accreditation.

1.0 SCOPE AND APPLICATION
1.1 Method 4435 is a bio-analytical procedure that is based on the mechanism of action of dioxin-like chemicals which allows for the determination of the relative toxic potential of sample extracts containing these chemicals and the resulting potency values are expressed as Toxic Equivalents (TEQs). Method 4435 is a bio-analytical method that is based on the ability of dioxin and related chemicals to activate the Ah receptor (AhR), a chemical-responsive DNA binding protein that is responsible for producing the toxic and biological effects of these chemicals. Measurement of the level of activation of AhR-dependent gene expression by a chemical or chemical extract provides a measure by which to estimate the relative potency and toxic potential of these chemicals and/or extracts with resulting values expressed as Toxic Equivalents (TEQs).
Xenobiotic Detection Systems (XDS web site: www.dioxins.com) has a commercially available genetically engineered cell line that contains the firefly luciferase gene under trans-activational control of the AhR (U.S. patent # 5,854,010). This cell line can be used for the sensitive detection and relative quantification of AhR agonists and agonist activity of complex mixtures. Our term for the in vitro assay is the XDS Chemical-Activated Luciferase Expression or CALUX® by XDS assay. The most widely studied class of compounds that activate this system is the polychlorinated diaromatic hydrocarbons (PCDH), such as 2,3,7,8-tetrachlorodibenzo-p-dioxin
(2,3,7,8-TCDD, dioxin). The relative toxic and biological potency of many PCDH compounds are quantified and expressed relative to that of 2,3,7,8-TCDD, since this is one of the most potent activators of AhR-mediated effects, including gene transcription. This relative quantification approach generates overall potency values known as Toxic Equivalents (TEQs) and the results obtained from the CALUX® by XDS assay provide a measure of TEQs in a sample. By using XDS's sample processing procedures and an affinity column (U.S. Patent # 6,720,431) polychlorinated biphenyls (PCBs) can be separated from chlorinated dioxins/dibenzofurans (PCDDs/PCDFs) making it possible to determine what portion of the total TEQs of a sample is due to each of these classes of compounds. XDS has termed this the Dioxin/Furan- and PCBspecific(DIPS) analysis or the DIPS-CALUX bioassay for dioxin-like chemicals.
The AhR-dependent mechanism of the toxic and biological effects of dioxin-like chemicals and the basis of the CALUX® by XDS bioassay measurement and estimate of TEQ is [shown above] (Denison et al., 2004). The AhR receptor complex is capable of binding dioxins, furans, PCBs and other dioxin-like compounds. Once these chemicals bind to the AhR, the complex migrates into the nucleus where it specifically binds to the ARNT protein. The resulting chemical: AhR:ARNT complex then binds to a specific DNA sequence, the Dioxin Responsive Element (DRE), which is present upstream from many genes including that of CYP1A1, and this binding stimulates expression of the adjacent gene. In the case of the CALUX® by XDS assay, a plasmid containing four DREs immediately upstream of the firefly luciferase reporter gene was stably transfected into the mouse Hepa1c1c7 cell line to produce the recombinant cell line H1L6.1c3 (6.1 cells). This transformed cell line responds to toxic PCDDs, PCDFs and PCBs, and high molecular weight polynuclear aromatic hydrocarbons (PAHs) with the dose-dependent induction of firefly luciferase (Garrison et al., 1996; Denison et al., 2002, 2004; Ziccardi et al., 2002; Han et al., 2004). Comparison of these results to a 2,3,7,8-TCDD standard curve for induction allows for determination of the TEQs in a given sample.
By using XDS sample processing methods (U.S. patent # 6,720,431) it is possible to separate polyhalogenated biphenyls from polyhalogenated dioxins/dibenzofurans present in the same sample. Using this DIPS-CALUX® bioassay it is possible to determine the portion of the total TEQ activity in a given sample that is due to each of these classes of compounds (Brown et.,al 2002).
NOTE: The bioassay testing product listed in this method has been submitted to EPA, evaluated by the Agency, and found to meet the performance specifications necessary for inclusion in SW-846. As additional testing products are evaluated by EPA and found to provide equivalent performance, information will be made available by the Office of Solid Waste regarding those testing products that are capable of meeting the performance specifications in this method
 (See http://www.epa.gov/epaoswer/hazwaste/test/pdfs/kits.pdf).  However, this procedure will not be revised solely to include information on additional testing products. Descriptions and materials lists for products relevant to this method are provided in Table 3 and are given in the manufacturer’s literature.
1.2 The CALUX® by XDS method for TEQ estimation of dioxin-like chemicals. The CALUX® by XDS method is a relatively rapid screening method capable of estimating the Toxic Equivalents (TEQs) concentration for dioxin-like chemicals in a sample.  The sample is extracted in an organic solvent and fractionated through the sample processing procedure. An extract that contains the halogenated dioxins/furans is separated from an extract containing the halogenated biphenyls. These extracts are applied to monolayers of our H1L6.1c3 cells and the amount of luciferase induction is measured after 20 to 24 hours. A standard dilution series of 2,3,7,8-TCDD is included on each plate of cells.
Estimation of dioxin/2,3,7,8-TCDD-like TEQ activity present in the sample extract is performed by extrapolation to the 2,3,7,8-TCDD standard curve by least squares estimates with the 4 parameter Hill Equation.
There are three modes by which the DIPS-CALUX bioassay is performed. These are the screening mode with historical recovery, screening mode surrogate recovery, and the semiquantitative mode. The screening mode involves the analysis of a single aliquot of the sample and recovery is estimated from the mean of historical recoveries that have been obtained for soils/sediment samples. This is considered to be acceptable as the variability of recoveries for soils/sediment samples has been relatively small (76.2 +/- 8.5%). Using this mode would indicate whether a sample needed to be further analyzed by either the semi-quantitative mode or by chemical analysis. The screening mode surrogate recovery, involves processing two aliquots of the sample, the first for analysis in the DIPS-CALUX bioassay and the second used for the surrogate spike with radiolabeled 2,3,7,8- TCDD to estimate recovery. The semiquantitative mode involves analyzing three aliquots of the sample in the DIPS-CALUX bioassay and a fourth aliquot of the sample used for determination of recovery with radiolabeled 2,3,7,8- TCDD. The cost of sample analysis is dependent upon which mode of the DIPS-CALUX bioassay is used for estimation of the levels of sample contamination.

1.3 Toxic Equivalents (TEQs):
The concept of Toxic Equivalents (TEQs) has been promulgated by the World Health
Organization to provide a means of quantifying for risk assessment purposes the toxicity of a family of chemicals with a similar overall mechanism of toxicity (Van den Berg, 1998). The family of dioxin-like chemicals (PCDHs) within this group includes 7 chlorinated dibenzo-p-dioxin congeners with 4 to 8 chorines on the molecule, 10 chlorinated dibenzofuran congeners with 4 to 8 chlorines on the molecule, and 12 chlorinated biphenyls with 4 to 10 chlorines on the molecule.

16.0 REFERENCES
Brown, D. J., Nakamura, M., Chu, M.D., Denison, M.S., Murata, H., and Clark, G.C.
(2002). "Recovery determinations for bioassay analysis: Condierations and results."
Organohalogen Compounds 58: 357-360.
Brown, D. J., Van Overmeire, I., Goeyens, L., Chu, M.D., Denison, M.S., and Clark, G.C.(2002). "Elimination of interfering compounds in preparation for analysis by an Ah receptor based bioassay." Organohalogen Compounds 58: 401-404.
Clark, G., V. Garry, et al. (2002). "Relationships between exposure to dioxin-like
chemicals, testosterone levels, and sex of the children of pesticide applicators."
Organohalogen Compounds 56: 73-76.
Clark, G. C., Brown, D.J., Seidel, S.D., Phelan, D., Denison, M.S. (1999).
"Characterization of the CALUX and GRAB bioassays for sensitivity and specificity in
detection of phamacological agents that activate the Ah Receptor signaling system."
Organohalogen Compounds 42: 309-312.
Clark, G. C., Chu, M., Touati, D., Rayfield, B., Stone, J., Cooke, M. (1999). "A Novel
Low-Cost Air Sampling Device (AmbStack Sampler) and Detection System (CALUX
Bioassay) for Measuring Air Emissions of Dioxin, Furan, and PCB on a TEQ Basis
Tested With a Model Industrial Boiler." Organohalogen Compounds 42: 309-312.
Denison, M. S., Nagy, S.R., Clark, G.C., Chu, M., Brown, D.J., Murata, H., Shan, G.,
Sanborn, J.R., and Hammock, B.D. (2001). "Bioanalytical approaches for the Detection
of Dioxin and Related Halogenated Aromatic Hydrocarbons." Organohalogen
Compounds 45.
Denison, M. S., Seidel, S.D., Ziccardi, M., Rogers, W.J., Brown, D.J., and Clark, G.C.
(1999). "Ah receptor-based bioassays for dioxins and related chemicals: Applications
and limitations." Organohalogen Compounds 40: 27-30.
Denison, M.S., Zhao, B., Baston, D.S., Clark, G.C., Murata, H. and Han, D.-H. (2004)
Recombinant Cell Bioassay Systems for the Detection and Relative Quantitation of
Halogenated Dioxins and Related Chemicals, Talanta 63: 1123-1133.
Denison, M.S. Nagy, S.R., Ziccardi, M., Clark, G.C., Chu, M., Brown, D.J., Shan, G.,
Sugawara, Y., Shirley J. Gee, S.J., James Sanborn, J. and Hammock, B.D. (2002)
Bioanalytical approaches for the detection of dioxin and related halogenated aromatic
hydrocarbons, in: Technology-Driven Biomarkers Development and Application in
Environmentally-Associated Diseases, Wilson, D. and W. Suk, W., eds., pp. 483-494,
Lewis Press, Boca Raton, FL.
Garrison, P.M., Tullis, K., Aarts, J.M.M.J.G., Brouwer, A. and Giesy, J.P. and Denison,M.S. (1996) Species-specific recombinant cell lines as bioassay systems for the detection of 2,3,7,8-tetrachlorodibenzo-p-dioxin-like chemicals, Fund. Appl. Toxicol. 30,194-203.
Han, D.-H., Nagy, S.R. and Denison, M.S. (2004) Comparison of recombinant cell Bioassays for the detection of Ah receptor agonists, Biofactors 20, 11-22.
Han, D., Nagy, S.R., and Denison, M.S. (2002). "Recombinant cell lines for the detection of dioxins and Ah Receptor ligands- Not all assays are created equal." Organohalogen Compounds 58: 421-424.
Ziccardi, M.H., Gardner, I.A. and Denison, M.S. (2002) Application of the luciferase
recombinant cell culture bioassay system for the analysis of polycyclic aromatic
hydrocarbons, Environ. Toxicol. & Chem. 21, 2027-2033.
Windal, I., Dennison, M. S, Birnbaum L. S., Van Wouwe, N., Baeyens, W. Goeyens L.
(2005). “Chemically Activated Luciferase Gene Expression (CALUX) Cell Bioassay
Analysis for the Estimation of Doxin-Like Activity: Critical Parameters of the CALUX
Procedure that Impact Assay Results, Environ.” Sci. Technol., 3, 7357-7364.
Van den Berg et al (2006). “The 2005 World Health Organization Reevaluation of
Human and Mammalian Toxic Equivalency Factors for Dioxins and Dioxin-Like
Compounds.” Toxicological Sciences 93(2):223-241.










www.dioxins.com/pdf/environment/environment09.pdf

How to measure dioxins in a smokestack using CALUX


Analysis P006
ORGANOHALOGEN COMPOUNDS


Vol.40 (1999) pp. 79-82
A Novel Low-Cost Air Sampling Device (AmbStack Sampler) and Detection System (CALUX Bioassay) for Measuring Air Emissions of Dioxin, Furan, and PCB on a TEQ Basis Tested With a Model Industrial Boiler
George C. Clark 1, Michael Chu 1, Dahman Touati 2, Barry Rayfield 3, Jon Stone 4, and Marcus Cooke 5
Affilitations: 1 Xenobiotic Detection Systems, Durham, NC, 2 Arcadis, Durham, NC, 3 Kilkelly Associates, Raleigh, NC, 4 URG, Chapel Hill, NC, 5 Cooke Companies International, Chapel Hill, NC

Introduction

The analysis of polychlorinated dibenzo-p-dioxin (PCDD) and polychlorinted dibenzofuran (PCDF) in gaseous samples is very labor intensive, and expensive. Regulatory reporting usually requires a sampling team and several days collect multiple samples. Shipping too is complicated by the use of organic solvent rinses and numerous subsamples that require complex and expensive shipping.Sample analysis, after collection, is also expensive. Multiple clean up steps are needed, and expensive instrumentation is used, such as high resolution gas chromatography (HRGC) coupled to high resolution mass spectrometry (HRMS). A low cost unitized sampling system, the "AmbStack Sampler" was designed by our group, and combined with a reporter gene bioassay system, the "CALUX" method, to give accurate PCDD/PCDF analyses with much simpler techniques than are currently in use. The AmbStack/CALUX system provides reliable air emission data at a fractional cost of conventional emission methods.This system has been demonstrated for ambient sampling, low temperature stack emissions, and simulated industrial boiler discharges. The sampling unit, called the "AmbStack Sampler”, is commercially available, and uses a polyurethane plug (PUF) insert in a glass sampling cartridge for ambient and stack sampling. AmbStack samples can be directly analyzed for PCDD, PCDF, PCB or polycyclic aromatic hydrocarbons (PAH). The AmbStack Sampler contains a glass probe-cartridge unit, and Teflon® connections a dry gas meter and air pump. After sampling, the probe-cartridge unit is sealed with Teflon®-lined end caps, and shipped directly to the laboratory for analysis. Sample extraction is done by in situ solvent extraction and clean up, followed by CALUX reporter gene bioassay.
Xenobiotic Detection Systems, Inc. (XDS) has a genetically engineered cell line which contains the firefly luciferase gene under trans-activational control of the aryl hydrocarbon receptor. This cell line can be used for the detection and quantification of AhR agonists. Exposure of this patented cell line to AmbStack sample extracts yields a direct measure of total TEQ since response of these cells is based on the mechanistic basis by which biologically active PCDD, PCDF, and PCB express their toxicity (1,2).
In the current experiments we demonstrate the sensitivity and performance of the AmbStack Sampler for PCDD/PCDF quantification on a TEQ basis, using the CALUX bioassay and a simulated industrial boiler discharge.

Materials and Methods

Incinerator Conditions

The combustion system used to perform this test was a North American Package Boiler (NAPB), which is capable of firing natural gas or #2 through #6 fuel oils. The boiler is a three pass firetube “Scotch” marine-type design fitted with a North American burner rated at 2.5 x106 Btu/hr. A dopant (a mixture of 1,2 dichlorobenzene and copper naphthenate) was injected through a separate injection system to the main fuel injection system prior to the burner. The dopant flow rate was adjusted to yield a HCl concentration at the stack of approximately 500 ppm at 7% O2. A Method 23 sampling train and the AmbStack sampler were placed at the same location in the stack. The flue gas stream for this experiment was stable at a temperature of about 140 oC with a mo isture level of about 11 %. Prior to testing the Boiler unit experienced a thermal decontamination process of about 400 hours.

AmbStack sampling and CALUX bioassay

The PUF insert was removed from the cartridge, and the flow direction noted. The forward or "front end" section of the PUF cartridge was separated from the remaining PUF and analyzed separately with the probe rinse, to determine an Apparent Collection Efficiency, ACE. The front 2/3 of the PUF insert was extracted using toluene , and combined with the toluene rinsate from the probe and the cartridge holder. The remaining back 1/3 section of the PUF insert was extracted separately.The front and back extracts were analyzed separately to determine if any sample breakthrough had occurred.
Sample extracts were split into equal aliquots , the first aliquot was prepared by our Method 1 cleanup procedure to measure TEQ activity of chlorinated species (PCDD, PCDF, and PCB). The second aliquot was prepared using our Method 2 Procedure which provides separate extracts to estimate TEQ for PCB and PCDD/PCDF individually. These proprietary clean up processes involve differential chromatography. All extracts were solvent exchanged into DMSO before analysis.
Sample extracts were suspended in cell culture medium. This media was applied to H1.1C2 mouse hepatoma cells (Patent # 5,854,010 ) grown in 96 well culture plates. In addition to sample dilutions a standard curve of 2,3,7,8-tectrachloro dibenzo-p-dioxin (TCDD) was assayed. All assays of standards and unknowns were run in duplicate. Plates were incubated for 4 hours in a humidified C02 incubator. Following incubation media was removed and cells observed microscopically for viability. Luciferase response, the induction of luciferase activity, was measured optically as total light emission using a BMG Luminometer.

Results

Cell viability: Microscopic examination of the cells following exposure to sample extracts did not reveal any indication of toxicity. Samples were analyzed and compared to a clean PUF blank.

Results of CALUX measurements of TEQ activity from the simulated industrial boiler extracts are presented in Table I.

TABLE I. CALUX RESULTS (NANOGRAM TEQ ACTIVITY PER SAMPLE)
Method 1
Total TEQ(PCDD/PCDF/PCB)A

Front End (2/3 PUF/Rinsate)
13.7 ± 3.6

Back End (1/3 PUF)
2.8 ± 0.6


PCDD/PCDFB
PCBC
SumD
Method 2
TEQ
TEQ
Total TEQs
Front End
12.1 ± 2.07
2.01 ± 0.44
14.1
Back End
2.2 ± 0.47
0.91 ± 0.11
3.1




___________________________________________________________________
A. Data are Mean ± Standard Deviation of 5 independent determinations in the CALUX assay for total TEQ activity.
B. Data are Mean ± Standard Deviation of 3 independent determinations in the CALUX assay for TEQ activity in a sample fraction purified for dioxins and furans.
C. Data are Mean ± Standard Deviation of 3 independent determinations in the CALUX assay for TEQ activity purified for planar PCB.
D. Data are the sum of TEQ determinations from PCDD/PCDF and PCB fractions.
Relative emission levels found in collected PUF samples are presented in Table II based on 3.58 M
3 air sampled during the 3 hour test period.

TABLE II. ANALYSIS OF AIR SAMPLES (NANOGRAM /METER3 TEQ ACTIVITY)

Method 1
Total TEQs
Front End
3.8
Back End
0.78
Apparent Collection Efficiency
83%


Method 2
TEQ                     TEQ                       Total TEQ

PCDD/PCDF       PCB                           Sum
Front End
   3.4                     0.56                             3.9



A comparison HRMS analysis was performed by collecting a parallel U.S. Environmental Protection Agency, Method 23 sample. The results of that analysis were 2.75 ng/dscm (7% O2) versus 1.9 ng/dscm (7% O2) by AmbStack and CALUX. The comparison analysis of AmbStack/CALUX showed excellent agreement with HRMS.

Discussion
The comparison analysis of AmbStack/CALUX showed excellent agreement with HRMS. The AmbStack Sampler, combined with CALUX TEQ quantification, gives a rapid and cost effective method to measure PCDD/PCDF emissions. The method was sensitive at concentrations found in a simulated industrial boiler emission. The CALUX screen proved to be rugged in analyzing this complex sample type. The clean up procedure was rapid and data reports were generated in two working days after sampling was complete.
Performance in this study suggests that the AmbStack/CALUX system, using PUF, is suitable for many ambient and industrial applications, such as post control emissions testing. This technique is especially useful as a low cost diagnostic tool to quickly measure dioxin emissions from thermal combustion systems.

References

1) Garrison, P.M., et al. Fund. Appl. Toxicol. 1996. 30, 194-203.
2) Denison, M.S., A. Brouwer, and G.C. Clark. U.S. patent # 5,854,010.

Acknowledgement

The authors would like thank Dr. Brian K. Gullet of the U.S. Environmental Protection Agency for
his assistance in arranging the boiler test, and facilitating sampling at the EPA Combustion
Research Facility at Research Triangle Park, NC.



Japanese analysis for ash and soil using CALUX

Full paper at:
http://www.dioxins.com/pdf/environment/environment10.pdf

Validation study for the use of the dioxin responsive CALUX assay for analysis of Japanese ash and soil samples
Brown D; Kishimoto Y; Ikeno O; Chu M; Nomura J; Murakami T; Murata H
Organohalogen Compounds 45:200, 2000
In Japan incineration is a common method for disposing of municipal waste and it is estimated that more than 10,000 incinerators of various capacities are currently in operation. In the past couple of years there has been an increased concern regarding the emission from these incinerators and other the emissions of other industries. In particular the concern has focused on the inadvertent production and release of chlorinate aromatic compounds such as polychlorinated biphenyls (PCBs), polychlorinated dibenzo--p-dioxins (PCDDs) and polychlorinated dibenzofurans (PCDFs). In August 1997 the Japanese government addressed these concerns by amending the cabinet orders of the Air Pollution Control Law and Waste Management and PubIic Cleansing Law. These amendments implemented stricter regulations on incinerators and other Industries that emit PCBs, PCDDs and PCDFs. These amendments pIaced an immediate limit on emissions from new facilities that will emit these compounds and provided for gradually more strict limits for existing facilities over a five-year period. In order to comply with these new limits it was expected that monitoring by chemical analysis would have to increase. This raised concerns that the chemical analysis by HRGCMS for compliance might be an economic hardship for some of the regulated industries and that the increased demand might outstrip the capacity of the existing analytical laboratories. Based on these concerns the Japanese government and private corporations began to examine the possibility of using alternative testing methods to monitor for the presence of these compounds. In this article we report the results from a preliminary validation study conducted by Hiyoshi Corporation and Xenobiotic Detection Systems, Inc (XDS). This study used a blinded format to compare the results from the dioxin  responsive CALUX  assay with HRGCMS data.
  The samples were extracted using a modification of the EPA 8290 extraction method
Briefly, the dried samples were ground and one gram aliquots were placed in solvent cleaned glass vials with PTFE lined caps.  The sample was extracted with a 20% solution of methanol in toluene then twice with toluene.  During each extraction step the samples were incubated in an ultrasonic water bath.  The three extracts from each sample were filtered, pooled and concentrated by vacuum centrifugation.  The sample extract was suspended in hexane and prepared for the bioassay by a proprietary clean up method.  The eluate from the clean up method was concentrated under vacuum into dimethyl sulfoxide (DMSO).  The DMSO solution was used to dose the genetically engineered cells in the CALUX assay. Prior to dosing the cells, the sample extracts in DMSO were suspended in cell culture medium.  This medium was then used to expose monolayers of the H1L1 cell line grown in 96 well culture plates.  In addition to the samples, a standard curve of 2,3,7,8-tetrachlorodibenzo-p-dioxin )TCDD) was assayed (161, 80.5, 40.2, 20.1, 10.1, 5.0, 2.5, 1.2 and 0.6 parts per trillion (ppt(  TCDD).  The plates were incubated for a time to produce optimal expression of the luciferase activity in a humidified CO2 incubator.  Following incubation, the medium was removed and the cells were examined microscopically for viability.  The induction of luciferase activity was  quantified using the luciferase assay kit from Promega.
Results and Discussion
From the GC/MS analysis of the samples, the I-TEQs were calculated using the TEF values for the individual congeners.  The sample I-TEQs were estimated by the CALUX assay by comparing the response of the sample extract to the standard curve for 2,3,7,8-TCDD. The correlation coefficient between the results is acceptable, (r = 0.94). 









How the Japanese do an air sample






Sampling

  Sample should be taken by a high volume air sampler with which a sampling tube with 2 pieces of polyurethane foam is attached below filter paper.  For obtaining a 24-hour average concentration, sample should be collected at a high flow rate of 700 L/min for 24 hours.  For obtaining a weekly average concentration, samples should be collected 7 times at a high flow rate of 700 L/min for 24 hours or collected continuously at a medium flow rate of 100 L/min for consecutive 7 days.  Glass fiber filter shall be used as the filter paper for a high-volume air sampler.

Solvent Extraction

Sample is extracted from glass fiber filter by Soxhlet extractor with toluene for 16 to 24 hours.  
For the polyurethane foam, sample is extracted by a Soxhlet extractor with acetone for 16 to 24 hours.